When it concerns ensuring safety in industrial, commercial, and property spaces, slip resistance testing is a crucial element. At ATTAR (Advanced Technology Testing & Research), we focus on floor slip resistance testing, concrete moisture testing, and luminance contrast analysis to assist services and homeowner alleviate threats and abide by security requirements.

With advanced devices such as the pendulum slip test maker and moisture meter for concrete, we offer precise and independent slip testing services throughout Australia. Our competence covers ASTM F2170 compliance, R Score evaluations, P Score tiles, and more, ensuring your floors fulfill the greatest safety benchmarks.

Why Slip Resistance Testing is Important


Slips and falls are among the leading causes of work environment and public injuries. Correct slip testing assists recognize harmful surface areas before mishaps take place. Whether you require damp pendulum test examinations or pendulum test for slip resistance, ATTAR delivers precise results to enhance safety.

Key Services Offered by ATTAR


1. Floor Slip Resistance Testing

- Pendulum slip test (AS 4663).
- R Ranking and P Ranking tiles evaluations.
- Independent slip testing services for compliance.

2. Concrete Moisture Testing

- Slab moisture test using advanced moisture meter for concrete.
- ASTM F2170 compliant assessments.
- Concrete slab moisture testing to prevent flooring failures.

3. Luminance Contrast Testing

- Guarantees exposure for aesthetically impaired people.
- Complies with Australian availability standards.

4. On-Site & Lab Testing

- Slip test maker for precise on-site examinations.
- Wet pendulum test for damp surface area slip resistance.

Comprehending Slip Resistance Ratings: R Rating vs. P Rating


When conducting slip resistance testing, two key classifications are used:.

- R Rating (Ramp Test - DIN 51130)
Steps slip resistance under lubricated conditions, typically used in Europe.

- P Score (Pendulum Test - AS 4586)
Evaluates vibrant friction utilizing a pendulum test slip resistance device, commonly adopted in Australia.

ATTAR provides independent slip testing to determine whether your flooring meets the required pendulum ranking tiles requirements.

The Importance of Concrete Moisture Testing


Excess moisture in concrete slabs can lead to floor covering failures, mold development, and adhesive deterioration. Our concrete moisture testing services include:.

> ASTM F2170 compliant in-situ relative humidity testing.
> Moisture meter for concrete assessments.
> Slab moisture test to ensure optimal conditions for floor setups.

By identifying moisture concerns early, we help prevent pricey repair work and guarantee lasting floor covering efficiency.

Luminance Contrast for Ease Of Access Compliance


Proper luminance contrast is crucial for aesthetically impaired individuals to browse spaces securely. ATTAR assesses:.

> Stair edges.
> Door frames.
> Handrails.
> Tactile indicators.

Our evaluations guarantee compliance with Australian Disability Standards (AS 1428.1).

Why Pick ATTAR for Slip Resistance & Moisture Testing?


> NATA Accredited (where appropriate).
> Advanced Testing Devices (pendulum slip test, moisture meters).
> Nationwide Service Coverage.
> Quick & Dependable Reporting.

For skilled slip resistance testing, floor slip resistance testing, and concrete moisture testing, contact ATTAR (Advanced Technology Testing & Research):.

Address: 44/48 Rocco Dr, Scoresby VIC 3179, Australia.
Phone: +61 1300 139 155.

Common Applications of Slip Resistance Testing


1. Commercial & Retail Spaces

Shopping center, dining establishments, and offices need safe flooring to prevent client and employee injuries. Our pendulum slip test makes sure compliance with safety guidelines.

2. Industrial & Warehouse Facilities

High-traffic commercial environments need durable, slip-resistant floor covering. ATTAR's slip testing services help preserve workplace security.

3. Healthcare & Aged Care Facilities

Hospitals and retirement home must lessen slip risks. Our luminance contrast and slip resistance testing make sure safe mobility for patients and personnel.

4. Public Infrastructure

Paths, train stations, and government structures need independent slip testing to meet availability and safety requirements.

How ATTAR Conducts Slip Resistance Testing


Step 1: Surface Area Evaluation

We evaluate floor covering products and conditions (dry, wet, or polluted).

Action 2: Pendulum Slip Test (AS 4663)

Using a slip test device, we determine the dynamic coefficient of friction (DCOF).

Step 3: Wet Pendulum Test

Imitates slippery conditions to assess real-world slip risks.

Step 4: Reporting & Compliance Certification

Comprehensive reports with R Score or P Score tiles categories.

The Science Behind Pendulum Slip Testing


The pendulum test slip resistance approach includes a swinging arm with a rubber slider that simulates a foot's motion. The test procedures:.

- Slip Possible Worth (SPV).
- Pendulum ranking tiles category (P0 to P5).

Greater rankings (P4/P5) show much better slip resistance.

Moisture Testing for Concrete Floors: Avoiding Failures


Moisture-related floor covering failures can be pricey. ATTAR's concrete slab moisture testing consists of:.

- ASTM F2170 in-situ RH probes.
- Moisture meter for concrete check.
- Slab moisture test information analysis.

Conclusion


ATTAR (Advanced Technology Testing & Research) is Australia's relied on company of slip resistance testing, floor slip resistance testing, concrete moisture testing, and luminance contrast evaluations. With advanced technology like the pendulum slip test and moisture meter for concrete, we provide accurate, independent, and compliant testing Concrete Moisture Content For Flooring services.

Ensure your property meets security requirements-- contact ATTAR today:.

44/48 Rocco Dr, Scoresby VIC 3179, Australia.
+61 1300 139 155.

By picking ATTAR, you purchase independent slip testing services, pendulum test slip resistance precision, and long-term floor safety solutions. Let us assist you develop much safer, compliant, and moisture-resistant environments.

Report this page